【廣告】
(一) 型號說明:
以250HW-8為例:
250—泵進(出)水口直徑為250毫米。
8—泵總揚程為8米。
III. Type Instruction:
Take 250HW-8 for an example:
250-The diameter of inlet /outlet of pump is 250mm.
8-The total head of pump is 8m.
5、水泵有雜音或振動
There is noise
in pump or the pump is vibrating
1、軸中心沒有對正
2、軸彎曲軸承磨損過大
3、葉輪平衡性差
4、地腳螺栓松動
5、裝置不當
6、葉輪局部阻塞
7、吸水高度太高、發(fā)生汽蝕
8、泵內掉進雜物
1.The axile center is not aligning
2.The axile is bend, the bearing wears
much
3.The balance of impeller is not good
4.The foundation bolts are loose
5.The assembly is improper
6.Part of the impeller is blocked
7.The suction head is too high to produce
cavitation
8.There are sundries in pump.
1、找正
2、校正或更換軸承
3、進行靜平衡試驗和調整
4、擰緊
5、檢查機組
6、消除雜物
7、降低安裝位置減低安裝高度
8、清除雜物
1.Calibrate
2.Calibrate it or change the bearing
3.Do the static balancing test and adjust
it
4.Tighten it
5.Check the pump unit
6.Remove the sundries
7.Reduce the installation site to reduce
the installation height
8. Remove the sundries
Failure Casues and Resolving Methods
故障現(xiàn)象
Failures
原 因
Reas
消 除
方 法
Methods
1、水泵不出水
No water are
runing out
1、引水不夠真空泵抽吸空氣不盡
2、進水管路進氣
3、水泵轉速太低
4、吸程太高
5、水泵轉向不對
6、輸水高度超過規(guī)定
1.The diversion is not engouth or the
vacuum pump does not remove all air
2.Air suction for inlet pipes
3.The rotate speed of pump is too low
4.Suction head is too high
5.The turnning direction is not right
6.Water delivery height exceeds stated
one.
1、繼續(xù)加灌或抽氣
2、檢查并堵塞之
3、用轉速表檢查予以調整
4、降低安裝位置減少吸程
5、改變旋轉方向
6、減少輸水高度
1.Continue filling or removing air
2.Check and seal it
3.Check by tachometer and adjust it
4.Reduce the installation po ition,
reduce the suction head
5.Change the turnning direction
6. Reduce water delivery height
企業(yè): 泰安金石泵業(yè)有限公司
手機: 13605386905
電話: 0538-6202947
地址: 山東省泰安市泰山區(qū)南關路12號